Sfoglia per Autore
The effect of fixture neck design in a realistic model of dental implant: a finite element model.
2003-01-01 Necchi, Silvia; Migliavacca, Francesco; Gastaldi, Dario; M., Pizzagalli; Del, Fabbro; R., Weinstein; Pietrabissa, Riccardo; Dubini, GABRIELE ANGELO
Computational fluid dynamics simulations in realistic 3-D geometries of the total cavopulmonary anastomosis: the influence of the inferior caval anastomosis.
2003-01-01 Migliavacca, Francesco; Dubini, GABRIELE ANGELO; E. L., Bove; M. R., DE LEVAL
Computational study on vascular reaction to deployment of stainless and shape memory alloy coronary stents
2004-01-01 Migliavacca, Francesco; Petrini, Lorenza; P., Massarotti; S., Schievano; F., Auricchio; Dubini, GABRIELE ANGELO
New trends in tissue engineered cartilage: microfluid dynamics in 3-d engineered cell systems
2004-01-01 Boschetti, Federica; Raimondi, Manuela Teresa; M., Cioffi; Migliavacca, Francesco; Pietrabissa, Riccardo
A study of mathematical modelling of the competitions of flow in the cavopulmonary anastyomosis with persistent forward flow
2004-01-01 Migliavacca, Francesco; Pennati, Giancarlo; Dubini, GABRIELE ANGELO; M., De Leval
MRI-based multiscale models for the haemodynamic structural evaluation of surgically reconstructed aortic arches
2004-01-01 S., Pittaccio; Migliavacca, Francesco; Dubini, GABRIELE ANGELO; E., Pedersen; E., Frund; V., Hjortdal; M., De Leval
Application of the multiscale approach to investigate fluidynamics in surgical procedures for the treatment of congenotal heart diseases
2004-01-01 Balossino, Rossella; Lagana', Katia; Migliavacca, Francesco; Pennati, Giancarlo; Dubini, GABRIELE ANGELO; M., De Leval; E., Bove
The effect of the position of an additional systemic-to-pulmonary shunt on the fluid dynamics of the bidirectional cavo-pulmonary anastomosis.
2004-01-01 Gervaso, Francesca; S., Kull; Pennati, Giancarlo; Migliavacca, Francesco; Dubini, GABRIELE ANGELO; V., Luisi
Ten years of modelling to achieve haemodynamic optimisation of the total cavopulmonary connection.
2004-01-01 Dubini, GABRIELE ANGELO; Migliavacca, Francesco; Pennati, Giancarlo; M. R., DE LEVAL; E. L., Bove
Assessment by computational and in vitro studies of the blood flow rate through modifed Blalock Taussig shunts
2004-01-01 Pennati, Giancarlo; Migliavacca, Francesco; Gervaso, Francesca; Dubini, GABRIELE ANGELO
The effect of media perfusion on three-dimensional cultures of human chondrocytes: Integration of experimental and computational approaches
2004-01-01 Raimondi, MANUELA TERESA; Boschetti, Federica; L., Falcone; Migliavacca, Francesco; A., Remuzzi; Dubini, GABRIELE ANGELO
Contact stresses and fatigue life in a knee prosthesis: comparison between in vitro measurements and computational simulations
2004-01-01 Villa, TOMASO MARIA TOBIA; Migliavacca, Francesco; Gastaldi, Dario; M., Colombo; Pietrabissa, Riccardo
Computational fluid dynamic study of flow optimization in realistic models of the total cavopulmonary connections.
2004-01-01 T. Y., Hsia; Migliavacca, Francesco; S., Pittaccio; A., Radaelli; Dubini, GABRIELE ANGELO; Pennati, Giancarlo; M. R., DE LEVAL
Global mathematical modelling of the Norwood circulation: a multiscale approach for the study of the pulmonary and coronary arterial perfusions.
2004-01-01 Migliavacca, Francesco; Lagana', Katia; Pennati, Giancarlo; M. R., DE LEVAL; E. L., Bove; Dubini, GABRIELE ANGELO
Percutaneous valve replacement: an engineer’s perspective
2004-01-01 Migliavacca, Francesco; S., Schievano; Dubini, GABRIELE ANGELO; A., Taylor; Y., Boudjemline; S., Kambadkone; P., Bonhoeffer
Numerical investigation of the intravascular coronary stent flexibility
2004-01-01 Petrini, Lorenza; Migliavacca, Francesco; F., Auricchio; Dubini, GABRIELE ANGELO
Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall
2004-01-01 Migliavacca, Francesco; Petrini, Lorenza; P., Massarotti; S., Schievano; F., Auricchio; Dubini, GABRIELE ANGELO
CFD and paediatric cardiac surgery
2004-01-01 Migliavacca, Francesco
Numerical simulations of drug release from eluting stents
2004-01-01 Dubini, GABRIELE ANGELO; Migliavacca, Francesco; Borghi, A.; E., Foa
Dispositivi a memoria di forma
2005-01-01 Dubini, GABRIELE ANGELO; Migliavacca, Francesco; Petrini, Lorenza
Legenda icone
- file ad accesso aperto
- file disponibili sulla rete interna
- file disponibili agli utenti autorizzati
- file disponibili solo agli amministratori
- file sotto embargo
- nessun file disponibile